Allgemeine Information

VD 0,5 Eca R100 R3000 ROOD VD 0,5 Eca R100 R3000 ROOD
YESSS-Bestellnummer
3002-9470
Produktcode
N000014
EAN-Code
05413260587238
Produktgruppe
Power cable < 1 kV, for permanent installation
Marke
Eupen
Serie
cables
Typ
VD 0,5

Produktbeschreibung

VD 0,5 Eca R100 R3000 ROOD

Produktspezifikationen

Conductor material
Copper
Conductor surface
Bare
Nominal cross section conductor
0.5 mm²
AWG size
0000
Nominal cross section conductor (AWG)
0 kcmil
Diameter conductor
0.81 mm
Conductor category
Class 1 = solid
Number of cores
1
Twisted cores
Nein
Material core insulation
Polyvinyl chloride (PVC)
Specification core insulation
Other
Core identification
Colour
Core colour
Several
Max. permitted conductor temperature
70 °C
Screen
Nein
Drain wire
Nein
Protective barrier
None
Armouring/reinforcement
None
Material outer sheath
None
Specification material outer sheath
Other
Colour outer sheath
Red
Reaction-to-fire according to EN 13501-6: Class
Eca
Reaction-to-fire according to EN 13501-6: Smoke production
None
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
None
Reaction-to-fire according to EN 13501-6: Acidity
None
Low temperature resistant according to EN 60811-504+505+506
Ja
Oil resistant according to EN IEC 60811-404
Nein
Outer diameter approximate
2 mm
Permitted cable outer temperature during assembling/handling
5 - 50 °C
Permitted cable outer temperature after assembling without vibration
-25 - 70 °C
Nominal voltage U0
300 V
Min. permitted bending radius, stationary application/permanent installation
12 mm
Nominal voltage U
500 V
Conductor resistance at 20 °C
36 Ohm/km
Core identification according to HD 308 S2
Ja
Identification/coding colour core
Other
With protective conductor
Nein
Cable geometry
Round
Shape of conductor
Round
Suitable as installation cable
Ja
Certified for shipboard application
Nein
Certified as airport lighting cable
Nein
Weight
8.5 kg/km
Lead sheath
Nein
Radial water blocking cable
Nein
Number of pilot/reduced conductors
0
Suitable for underground installation
Nein
Circuit integrity according to BS 6387 CWZ
Nein
Circuit integrity according to BS 8434-2
Nein
Circuit integrity according to BS 8491
No
Flame retardant according to IEC 60332-1-2
Ja
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
Nein
Flame retardant according to IEC 60332-3-22 (Cat A)
Nein
Flame retardant according to IEC 60332-3-23 (Cat B)
Nein
Flame retardant according to IEC 60332-3-24 (Cat C)
Nein
Flame retardant according to IEC 60332-3-25 (Cat D)
Nein
Low smoke according to EN IEC 61034-2
Nein
Halogen free according to EN IEC 60754-1
Nein
Halogen free according to EN IEC 60754-2
Nein
Halogen free according to EN IEC 60754-3
Nein
Circuit integrity according to IEC 60331-1
None
Circuit integrity according to IEC 60331-2
None
Circuit integrity according to IEC 60331-3
None
Circuit integrity according to EN 50200
None
Circuit integrity according to EN 50200 annex E
Nein
Number of strands per conductor
1
Strand diameter
0.81 mm
Website des Herstellers.