Add to selection
YMvK 5G4 mm² 0,6/1 kV Dca-s2,d2,a3
- 3043-7717
- |
- YMVKD2032050
243 meter
in stock
Don’t have an account? Request account
-
Over 6.000 products in stock
-
Order before 17:00 and receive your order the next working day!
- Need help? Call --- --- or contact us via email at [email protected]
General information
YMvK 5G4 mm² 0,6/1 kV Dca-s2,d2,a3
YMvK 5G4 mm² 0,6/1 kV Dca-s2,d2,a3
Ordercode YESSS
3043-7717
Product code
YMVKD2032050
EAN code
08717714114405
Product group
Power cable >= 1 kV, for permanent installation
Brand
Dynamic
Serie
YMvK Dca
Type
installatiekabel
Product description
XLPE installatiekabel YMvK 5G4 mm² 0,6/1 kV Dca-s2,d2,a3
Product specifications
Conductor material
Copper
Conductor surface
Bare
Nominal cross section conductor
4 mm²
Conductor category
Class 1 = solid
Shape of conductor
Round
Number of cores
5
Material core insulation
Polyolefin
Specification core insulation
Crosslinked polyethylene (XLPE)
Core identification
Colour
Laminated sheath
No
Fibre optic elements
No
Inner semi-conducting layer
No
Outer semi-conducting layer
No
Screen
No
Drain wire
No
Lead sheath
No
Number of pilot/reduced conductors
0
Concentric conductor
None
Material outer sheath
Polyvinyl chloride (PVC)
Colour outer sheath
Grey
Conductive coating
No
Longitudinal water blocking conductors
No
Longitudinal water blocking screen
No
Reaction-to-fire according to EN 13501-6: Class
Dca
Reaction-to-fire according to EN 13501-6: Smoke production
s2
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
d2
Reaction-to-fire according to EN 13501-6: Acidity
a3
Halogen free according to EN IEC 60754-2
No
Low smoke according to EN IEC 61034-2
No
Outer diameter approximate
14.6 mm
Min. permitted bending radius, stationary application/permanent installation
88 mm
Max. permitted conductor temperature
90 °C
Permitted cable outer temperature during assembling/handling
0 - 80 °C
Permitted cable outer temperature after assembling without vibration
-40 - 80 °C
Nominal voltage U0
0.6 kV
Nominal voltage U
1 kV
Conductor resistance at 20 °C
4.61 Ohm/km
Core identification according to HD 308 S2
Yes
With protective conductor
Yes
Cable geometry
Round
Weight
390 kg/km
Suitable as installation cable
Yes
Certified for shipboard application
No
Suitable as medium-voltage cable
No
Suitable as high-voltage cable
No
Certified as airport lighting cable
No
Diameter conductor
2.26 mm
Protective barrier
None
Armouring/reinforcement
None
Radial water blocking cable
No
Cable width approximate
14.6 mm
Cable height approximate
14.6 mm
Suitable for underground installation
Yes
With rodent protection
No
Flame retardant according to IEC 60332-1-2
Yes
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Flame retardant according to IEC 60332-3-24 (Cat C)
Yes
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Halogen free according to EN IEC 60754-1
No
Halogen free according to EN IEC 60754-3
No
Circuit integrity according to IEC 60331-1
None
Circuit integrity according to IEC 60331-2
None
Circuit integrity according to IEC 60331-3
None
Circuit integrity according to EN 50200
None
Circuit integrity according to EN 50200 annex E
No
Oil resistant according to EN IEC 60811-404
No
Number of strands per conductor
1
Strand diameter
2.26 mm