Miniature circuit breaker 400 V 6 kA, 2-pole, B, 10

Add to selection
General information
Ordercode YESSS
3071-1149
Product code
5SJ62106KS
EAN code
04001869324036
Product group
Miniature circuit breaker (MCB)
Brand
Siemens AG
Type
CIRCUIT BREAKER 6KA 2POL B10 SKL
Miniature circuit breaker 400 V 6 kA, 2-pole, B, 10 Miniature circuit breaker 400 V 6 kA, 2-pole, B, 10 A, D=70 mm with sc
STOCK
IN STOCK
0 piece
Product description

Miniature circuit breaker 400 V 6kA, 2-pole, B, 10A, D=70 mm with screwless outgoing terminals The miniature circuit breaker is the fuse for short-circuit protection. The miniature circuit breakers from Siemens, as an important component of the SENTRON protective components for electronic installations, provide effective protection for personnel and plants by reliably shutting down in the event of an overload or short-circuit. User-friendly mounting and connection technology, standardized additional components and an integrated design - these are the characteristics of the device family. Whether forinfrastructure or for industrial requirements, Siemens provides miniature circuit breakers for all applications and every application area. The Siemens miniature circuit breakers are characterized primarily by: 1. Effective personnel, investment and plant protection against overload and short-circuits. 2. Reliable safety during installation due to standard reach-around and touch protection. 3. The data matrix code on the front of the device provides quick and easy access to information on all aspects of miniature circuit breakers. 4. Optimized technology for your safety - only from Siemens.

Product specifications
Release characteristic
B
Number of poles (total)
2
Rated current
10 A
Rated voltage
400 V
Rated insulation voltage Ui
440 V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
6 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
6 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
6 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
6 kA
Voltage type
AC/DC
Current limiting class
3
Concurrently switching neutral conductor
No
Overvoltage category
3
Pollution degree
2
Additional equipment possible
No
Width in number of modular spacings
2
Built-in depth
70 mm
Ambient temperature during operating
-25 - 45 °C
Connectable conductor cross section multi-wired
0.75 - 25 mm²
Connectable conductor cross section solid-core
0.75 - 25 mm²
Flush-mounted installation
No
Explosion-proof
No
more specifications
^