Circuit breaker, S0, motor protection, Class 10, A-release 27-32 A,

Add to selection
General information
Ordercode YESSS
3068-8695
Product code
3RV20214EA100BA0
EAN code
04047621003054
Product group
Motor protection circuit-breaker
Brand
Siemens AG
Type
CIRCUIT-BREAKER SCREW CONNECTION...
Circuit breaker, S0, motor protection, Class 10, A-release 27-32 A, Circuit breaker, S0, motor protection, Class 10, A-release 27-32 A, sh
STOCK
IN STOCK
0 piece
Product description

Special type Circuit breaker size S0 for motor protection, CLASS 10 A-release 27...32 A N-release 400 A screw terminal Standard switching capacity Ambient temperature -50 °C 500 switching cycles Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, these compact and climate-proof circuit breakers are optimized for use in load feeders, as well as for IE3/IE4 motors, of course. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date - SIRIUS modular system.

Product specifications
Overload release current setting
27 - 32 A
Phase failure sensitive
Yes
Switch off technique
Magnetic
Rated operating voltage
690 - 690 V
Rated permanent current Iu
32 A
Rated operation power at AC-3, 230 V
7.5 kW
Rated operation power at AC-3, 400 V
15 kW
Type of electrical connection of main circuit
Screw connection
Device construction
Built-in device fixed built-in technique
With integrated auxiliary switch
No
With integrated under voltage release
No
Number of poles
3
Rated short-circuit breaking capacity Icu at 400 V, AC
25 kA
Degree of protection (IP)
IP20
Height
97 mm
Width
45 mm
Depth
97 mm