Circuit breaker, S0, motor protection, Class 10, A-release 4.5-6.3 A,

Add to selection
General information
Ordercode YESSS
3068-8628
Product code
3RV20211GA25
EAN code
04047621003429
Product group
Motor protection circuit-breaker
Brand
Siemens AG
Type
CIRCUIT-BREAKER SPRING-L. CONN. ...
Circuit breaker, S0, motor protection, Class 10, A-release 4.5-6.3 A, Circuit breaker, S0, motor protection, Class 10, A-release 4.5-6.3 A,
STOCK
IN STOCK
0 piece
Product description

Circuit breaker size S0 for motor protection, CLASS 10 A-release 4.5...6.3 A N-release 82 A Spring-type terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, these compact and climate-proof circuit breakers are optimized for use in load feeders, as well as for IE3/IE4 motors, of course. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date - SIRIUS modular system.

Product specifications
Overload release current setting
4.5 - 6.3 A
Phase failure sensitive
Yes
Switch off technique
Magnetic
Rated operating voltage
690 - 690 V
Rated permanent current Iu
6.3 A
Rated operation power at AC-3, 230 V
1.5 kW
Rated operation power at AC-3, 400 V
2.2 kW
Type of electrical connection of main circuit
Spring clamp connection
Device construction
Built-in device fixed built-in technique
With integrated auxiliary switch
Yes
With integrated under voltage release
No
Number of poles
3
Rated short-circuit breaking capacity Icu at 400 V, AC
100 kA
Degree of protection (IP)
IP20
Height
119 mm
Width
45 mm
Depth
97 mm
more specifications
^