FI/LB-schakelaar, 6 kA, 3-polig type A, 30 mA, B-Char, In:

  • 3071-2304
  • |
  • 5SU13366FP16
2 piece in stock
Login to order
Don’t have an account? Request account
  • Products Over 6.000 products in stock
  • Order before 17:00 and receive your order the next working day!
  • Need help? Call --- --- or contact us via email at [email protected]

General information

FI/LB-schakelaar, 6 kA, 3-polig type A, 30 mA, B-Char, In: FI/LB-schakelaar, 6 kA, 3-polig type A, 30 mA, B-Char, In: 16 A Un: 40
Ordercode YESSS
3071-2304
Product code
5SU13366FP16
EAN code
04001869577852
Product group
Earth leakage circuit breaker
Brand
Siemens AG
Serie
SENTRON 5SU1
Type
RCBO 3P 3MW 6kA Type A 30mA B16

Product description

aardlek/leidingbeveiligingsscha kelaar, 6 kA, 3P type A, 30 mA, B-Char, In: 16 A nominale spanning: 400 V Aardlek-/leidingbeveiliging SENTRON 5SU1 voor de gecombineerde bescherming tegen overbelasting, kortsluiting en foutstromen. Onze aardlek/leidingbeveiligingsschakelaars (RCBO) zijn VDE-getest en gecertificeerd volgens EN 61009-1, EN 61009-2-1. De dubbele kamerklemmen maken het aansluiten van leidingen met zeer uiteenlopende diameters heel eenvoudig. Aanvullende Siemens SENTRON beveiligingsschakelaars zijn snel en eenvoudig aan te sluiten op de kamrails 5ST3. De datamatrix op het apparaat geeft snel toegangtot alle technische gegevens in de Siemens Industry Online Support-app. De SENTRON-veiligheidsschakelaars kunnen met de universele toebehoren uit het modulaire systeem met vele functies worden uitgebreid. Optimale techniek voor uw veiligheid - alleen van Siemens.

Product specifications

Number of poles (total)
3
Number of protected poles
3
Rated voltage
400 V
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4000 kV
Rated current
16 A
Rated fault current
30 A
Leakage current type
A
Current limiting class
3
Rated short-circuit breaking capacity according to EN 61009
6 kA
Rated short-circuit breaking capacity according to IEC 60947-2
6 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
Disconnection characteristic
Undelayed
Surge current capacity
0.25 kA
Voltage type
AC
Release characteristic
B
Concurrently switching neutral conductor
No
With interlocking device
Yes
Overvoltage category
3
Pollution degree
3
Ambient temperature during operating
-25 - 40 °C
Width in number of modular spacings
3
Built-in depth
70 mm
Anti-nuisance tripping version
Yes
Degree of protection (IP)
IP20
Connectable conductor cross section solid-core
1 - 35 mm²
Connectable conductor cross section multi-wired
1 - 35 mm²
Power loss
2.3 W
Mounting method
DIN rail
Manufacturer's website