Disjoncteur pour protection de transformateur, de générateur et d'installation Siemens AG
Ajouter à la sélection
informations générales
Code de commande
3070-4317
Code produit
3VA64406KT412AA0
Code EAN
04042948864456
Groupe de produits
Disjoncteur pour protection de transformateur, de générateur et d'installation
Marque
Siemens AG
Série
MCCB_UL_FS600_400A_4P_65KA_ETU8_LSI
Circuit breaker 3VA6 UL frame 600 breaking capacity class H Circuit breaker 3VA6 UL frame 600 breaking capacity class H 65 kA @ 48
Description du produit

Circuit breaker 3VA6 UL Frame 600 breaking capacity class H 65kA @ 480V 4-pole, Line protection ETU856, LSI, In=400A overload protection, 100% rated Ir=160A...400A Short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) Ground-fault alarm message via EFB300 or COM without connection 3VA6 molded-case circuit-breaker with 8-fold ETU for system protection, 100% Rated Breaker, UL approval. As an important part of the SENTRON protective components for industrial and infrastructure applications, the 3VA UL molded case circuit breakers from Siemens provide effective plant and starter protection thanks to a reliable shutdown in the event of an overload or short-circuit. The 3VA UL sets standards in flexibility and the variety of modular accessories available. The 100% rated versions of the 3VA6 molded case circuit breaker can be continuously operated with 100% of the specified rated current. They are tested and certified to this end. In addition, the 3VA UL molded case circuit breaker is also optimally suited to mechanical engineers and switchboard manufacturers who export worldwide. In addition to the IEC Standard, the two series, the 3VA5 and 3VA6, also satisfy the UL Standard. All of the functions can thus be used for plants around the world. This variant of the 3VA molded case circuit breaker is characterized primarily by: 1. Compact design. 2. Available as a variant for line protection. 3. 100% rated breaker. 4. Available as a 3 and 4-pole version. 5. Four breaking capacity classes from 55 kA ... 150 kA at 480 V. 6. Depending on the frame size: Rated current 40 A ... 400 A. 7. Installation possible as fixed mounting, in plug-in design, in withdrawable design. 8. The series has a solid-state overcurrent release. 9. Has an integrated display for displaying measured values. 10. Integrated measuring function and optional communication connection via Modbus TCP, Modbus RTU, PROFINET and PROFIBUS. 11. Modular and easy-to-fit internal accessories with diverse functions.

Spécifications du produit
Courant permanent nominal Iu
400 A
Tension assignée
690 - 690 V
Courant de commutation de court-circuit limite nominal Icu à 400 V, 50 Hz
85 kA
Réglage de courant du déclencheur de surcharge
150 - 400 A
Plage de réglage du déclencheur de court-circuit retardé de courte durée
240 - 4000 A
Plage de réglage du déclencheur de court-circuit non retardé
600 - 600 A
Protection intégrée contre les mises à la terre accidentelles
Oui
Type de construction de l'appareil
Technique d'encastrement fixe pour appareil encastré
Adapté à un montage de profilés chapeaux
Non
Montage de profilés chapeaux en option
Non
Nombre de contacts auxiliaires à ouverture
0
Nombre de contacts auxiliaires à fermeture
0
Nombre de contacts auxiliaires à deux directions
0
Relais de signalisation de déclenchement disponible
Non
Nombre de pôles
4
Finition de l'élément d'actionnement
Levier
Appareil complet avec unité de protection
Oui
Commande motorisée intégrée
Non
Commande motorisée en option
Oui
Classe de protection (IP)
IP40
Avec déclencheur à sous-tension intégré
Non
plus de spécifications
^